hGH
zecen
DR1027
Availability: | |
---|---|
Quantity: | |
[INTENDED USE [
The kit has been designed for the quantitative determination of Human Growth Hormone (HGH) in human serum.
The method can be used for samples over the range of 0.02-50.00 ng/mL
High and low value calibrators: 1 bottle each, respectively added with different amounts of hGH antigen containing 0.5% BSA, 0.05% proclin300 Tris buffer (0.15M, PH7.5), the two calibrators hGH antigen concentrations were 24ng /mL, 3ng/mL;
hGH anti-reagent: 1 vial, fluorescein isothiocyanate (FITC)-labeled mouse monoclonal anti-hGH antibody (0.5 µg/mL), alkaline phosphatase (AP)-labeled mouse monoclonal anti-hGH antibody (0.5 µg/mL) µg/mL), Tris buffer (0.15M, pH 8.0) containing 0.5% BSA;
Magnetic particle reagent: 1 bottle, magnetic particle and goat anti-FITC antibody conjugate (1mg/mL), PB buffer containing 0.5% BSA (0.2M, PH8.0);
Quality control material: 1 bottle each for high and low points, respectively adding different amounts of hGH antigen containing 0.5% BSA, 0.05% proclin300 Tris buffer (0.15M, PH7.5), two quality control materials hGH antigen concentration 24ng/mL and 1ng/mL respectively.
Note: Reagents of different batches of kits are not allowed to be used interchangeably.
Test item | hGH |
Specification | 100 Test/Box for CIA series |
Component | Magnetic Beads |
Calibrator Low | |
Calibrator High | |
hGH Anti | |
Control 1 | |
Control 2 | |
Accessories Required But Not Provided | Substrate |
Washing solution | |
Sample material | Serum |
Sample volume | More than 200μL |
Storage | 2-8℃ |
[INTENDED USE [
The kit has been designed for the quantitative determination of Human Growth Hormone (HGH) in human serum.
The method can be used for samples over the range of 0.02-50.00 ng/mL
High and low value calibrators: 1 bottle each, respectively added with different amounts of hGH antigen containing 0.5% BSA, 0.05% proclin300 Tris buffer (0.15M, PH7.5), the two calibrators hGH antigen concentrations were 24ng /mL, 3ng/mL;
hGH anti-reagent: 1 vial, fluorescein isothiocyanate (FITC)-labeled mouse monoclonal anti-hGH antibody (0.5 µg/mL), alkaline phosphatase (AP)-labeled mouse monoclonal anti-hGH antibody (0.5 µg/mL) µg/mL), Tris buffer (0.15M, pH 8.0) containing 0.5% BSA;
Magnetic particle reagent: 1 bottle, magnetic particle and goat anti-FITC antibody conjugate (1mg/mL), PB buffer containing 0.5% BSA (0.2M, PH8.0);
Quality control material: 1 bottle each for high and low points, respectively adding different amounts of hGH antigen containing 0.5% BSA, 0.05% proclin300 Tris buffer (0.15M, PH7.5), two quality control materials hGH antigen concentration 24ng/mL and 1ng/mL respectively.
Note: Reagents of different batches of kits are not allowed to be used interchangeably.
Test item | hGH |
Specification | 100 Test/Box for CIA series |
Component | Magnetic Beads |
Calibrator Low | |
Calibrator High | |
hGH Anti | |
Control 1 | |
Control 2 | |
Accessories Required But Not Provided | Substrate |
Washing solution | |
Sample material | Serum |
Sample volume | More than 200μL |
Storage | 2-8℃ |