Availability: | |
---|---|
Quantity: | |
Product Advantage
The five items of high blood pressure are used to rule out secondary hypertension and determine the causes of high blood pressure. Based on the five test results of hypertension, it can help clinical guidance in selecting antihypertensive drugs, achieve individualized antihypertensive treatment, and achieve better therapeutic effects.
Technical Parameters
1. Principle: Glow Chemiluminescence based on Alkaline Phosphatase (ALP)
2. Separation: Magnetic Microbeads
3. FITC/anti-FITC connected bridge
4. Innovative Substrate
Product Uses
1. Renin: It is secreted by the kidneys. When its value increases, secondary hypertension related to renal artery stenosis, reninoma, etc. can be considered.
2. Angiotensin II: It is indirectly converted from angiotensinogen synthesized by the liver or tissue. The increase in this indicator may be related to renal artery stenosis, renin, etc.
3. Aldosterone: secreted by the zona glomerulosa of the adrenal gland. If the examination reveals elevated aldosterone, primary aldosteronism needs to be considered and can be differentiated from essential hypertension.
4. Adrenocorticotropic hormone: secreted by the adenohypophysis. Elevations in this hormone may be caused by conditions such as primary adrenal insufficiency and Cushing's syndrome.
5. Cortisol: It is secreted by the zona fasciculata of the adrenal glands. Elevation of this indicator should consider Cushing's syndrome
Product Operate Guide
[Applicable instruments]
POClia CLIA analyzer manufactured byTaizhou Zecen Biotech Co.,
Ltd., models:POClia 8, POClia minus, POClia plus, POClia auto.
[Sample requirements]
The sample type used is whole blood, other sample types may not get
accurate results, it is recommended to use whole blood for
testing.Collect samples using standard procedures.
Sample volume cannot be less than 200μL.
Store at 2-8℃: 24 hours, for longer storage periods: freeze to below -
20℃
Avoid repeated freezing and thawing cycles, stored samples should be
thoroughly mixed prior to use (Vortex mixer).
Please ask local representative of ZECEN for more details if you have any
doubt.
[Testing Method]
Note: Please read the instruction manual carefully before use. Working
conditions: room temperature (15~30°C); Relative humidity≤ 80%.
[Preparation before the test]
Before the test, all reagents should be put to room temperature, and
the instrument should be turned on for at least 30 minutes;
FAQ
1: What is the detection principle?
Magnetic particle chemiluminescence method
2: Is it tested on a closed instrument?
Yes, only applicable to analyzers produced by Zecheng?
3: What is the minimum order quantity?
We have stock"
Product Advantage
The five items of high blood pressure are used to rule out secondary hypertension and determine the causes of high blood pressure. Based on the five test results of hypertension, it can help clinical guidance in selecting antihypertensive drugs, achieve individualized antihypertensive treatment, and achieve better therapeutic effects.
Technical Parameters
1. Principle: Glow Chemiluminescence based on Alkaline Phosphatase (ALP)
2. Separation: Magnetic Microbeads
3. FITC/anti-FITC connected bridge
4. Innovative Substrate
Product Uses
1. Renin: It is secreted by the kidneys. When its value increases, secondary hypertension related to renal artery stenosis, reninoma, etc. can be considered.
2. Angiotensin II: It is indirectly converted from angiotensinogen synthesized by the liver or tissue. The increase in this indicator may be related to renal artery stenosis, renin, etc.
3. Aldosterone: secreted by the zona glomerulosa of the adrenal gland. If the examination reveals elevated aldosterone, primary aldosteronism needs to be considered and can be differentiated from essential hypertension.
4. Adrenocorticotropic hormone: secreted by the adenohypophysis. Elevations in this hormone may be caused by conditions such as primary adrenal insufficiency and Cushing's syndrome.
5. Cortisol: It is secreted by the zona fasciculata of the adrenal glands. Elevation of this indicator should consider Cushing's syndrome
Product Operate Guide
[Applicable instruments]
POClia CLIA analyzer manufactured byTaizhou Zecen Biotech Co.,
Ltd., models:POClia 8, POClia minus, POClia plus, POClia auto.
[Sample requirements]
The sample type used is whole blood, other sample types may not get
accurate results, it is recommended to use whole blood for
testing.Collect samples using standard procedures.
Sample volume cannot be less than 200μL.
Store at 2-8℃: 24 hours, for longer storage periods: freeze to below -
20℃
Avoid repeated freezing and thawing cycles, stored samples should be
thoroughly mixed prior to use (Vortex mixer).
Please ask local representative of ZECEN for more details if you have any
doubt.
[Testing Method]
Note: Please read the instruction manual carefully before use. Working
conditions: room temperature (15~30°C); Relative humidity≤ 80%.
[Preparation before the test]
Before the test, all reagents should be put to room temperature, and
the instrument should be turned on for at least 30 minutes;
FAQ
1: What is the detection principle?
Magnetic particle chemiluminescence method
2: Is it tested on a closed instrument?
Yes, only applicable to analyzers produced by Zecheng?
3: What is the minimum order quantity?
We have stock"